SIMATIC S7-1200, Digital output SM 1226, F-DQ 4x 24 V DC 2A, PROFIsafe, 70 mm overall width, up to PL E (ISO 13849-1)/ SIL3 (IEC 61508)

 

General information    
Product type designation SM 1226 F-DQ 4x 24 VDC    
Supply voltage    
permissible range, lower limit (DC) 20.4 V    
permissible range, upper limit (DC) 28.8 V    
power supply according to NEC Class 2 required No    
Input current    
from backplane bus 5 V DC, max. 125 mA    
Digital outputs    
● from load voltage L+, max. 170 mA    
Power loss    
Power loss, typ. 8 W    
Digital outputs    
Number of digital outputs 4    
● in groups of 1    
Short-circuit protection Yes    
Switching capacity of the outputs    
● with resistive load, max. 30 Hz    
● on lamp load, max. 10 Hz    
Output voltage    
● Rated value (DC) 24 V    
Output current    
● for signal "1" rated value 2 A    
● for signal "1" permissible range, max. 10 mA to 2.4 A    
● for signal "0" residual current, max. P-switch: 0.5 mA, maximum; M-switch: 0.5 mA, maximum    
Cable length    
● shielded, max. 200 m    
● unshielded, max. 200 m    
Interrupts/diagnostics/status information    
Diagnostics indication LED    
● for status of the outputs Yes    
Degree and class of protection    
IP degree of protection IP20    
Standards, approvals, certificates    
CE mark Yes    
cULus Yes    
FM approval Yes    
Highest safety class achievable in safety mode    
● Performance level according to ISO 13849-1 Category 4, PL e    
● SIL acc. to IEC 61508 SIL 3    
Probability of failure (for service life of 20 years and repair time of 100 hours)    
— Low demand mode: PFDavg in accordance with SIL3 < 1.00E-05    
— High demand/continuous mode: PFH in accordance with SIL3 < 4.00E-09    
Ambient conditions    
Free fall    
● Fall height, max. 0.3 m; five times, in product package    
Ambient temperature during operation    
● min. 0 °C    
● max. 55 °C    
● permissible temperature change 5°C to 55°C, 3°C / minute    
Ambient temperature during storage/transportation    
● min. -40 °C    
● max. 70 °C    
Air pressure acc. to IEC 60068-2-13    
● Storage/transport, min. 660 hPa    
● Storage/transport, max. 1 080 hPa    
Relative humidity    
● Operation at 25 ℃ without condensation, max. 95 %    
Mechanics/material    
Enclosure material (front)      
● Plastic Yes    
Dimensions    
Width 70 mm    
Height 100 mm    
Depth 75 mm    
Weights    
Weight, approx. 270 g    
  General information
  Product type designation SM 1226 F-DQ 4x 24 VDC
  Supply voltage
  permissible range, lower limit (DC) 20.4 V
  permissible range, upper limit (DC) 28.8 V
  power supply according to NEC Class 2 required No
  Input current
  from backplane bus 5 V DC, max. 125 mA
  Digital outputs
  ● from load voltage L+, max. 170 mA
  Power loss
  Power loss, typ. 8 W
  Digital outputs
  Number of digital outputs 4
  ● in groups of 1
  Short-circuit protection Yes
  Switching capacity of the outputs
  ● with resistive load, max. 30 Hz
  ● on lamp load, max. 10 Hz
  Output voltage
  ● Rated value (DC) 24 V
  Output current
  ● for signal "1" rated value 2 A
  ● for signal "1" permissible range, max. 10 mA to 2.4 A
  ● for signal "0" residual current, max. P-switch: 0.5 mA, maximum; M-switch: 0.5 mA, maximum
  Cable length
  ● shielded, max. 200 m
  ● unshielded, max. 200 m
  Interrupts/diagnostics/status information
  Diagnostics indication LED
  ● for status of the outputs Yes
  Degree and class of protection
  IP degree of protection IP20
  Standards, approvals, certificates
  CE mark Yes
  cULus Yes
  FM approval Yes
  Highest safety class achievable in safety mode
  ● Performance level according to ISO 13849-1 Category 4, PL e
  ● SIL acc. to IEC 61508 SIL 3
  Probability of failure (for service life of 20 years and repair time of 100 hours)
  — Low demand mode: PFDavg in accordance with SIL3 < 1.00E-05
  — High demand/continuous mode: PFH in accordance with SIL3 < 4.00E-09
  Ambient conditions
  Free fall
  ● Fall height, max. 0.3 m; five times, in product package
  Ambient temperature during operation
  ● min. 0 °C
  ● max. 55 °C
  ● permissible temperature change 5°C to 55°C, 3°C / minute
  Ambient temperature during storage/transportation
  ● min. -40 °C
  ● max. 70 °C
  Air pressure acc. to IEC 60068-2-13
  ● Storage/transport, min. 660 hPa
  ● Storage/transport, max. 1 080 hPa
  Relative humidity
  ● Operation at 25 ℃ without condensation, max. 95 %
  Mechanics/material
  Enclosure material (front)  
  ● Plastic Yes
  Dimensions
  Width 70 mm
  Height 100 mm
  Depth 75 mm
  Weights
  Weight, approx. 270 g