General information |
Product type designation |
CB 1241 RS 485 |
Input current |
from backplane bus 5 V DC, typ. |
75 mA |
Power loss |
Power loss, typ. |
0.4 W |
Interfaces |
Interfaces/bus type |
RS 485 |
Number of interfaces |
1 |
Point-to-point connection |
● Cable length, max. |
1 000 m |
Integrated protocol driver |
— Freeport |
Yes |
— ASCII |
Yes; Available as library function |
— Modbus RTU master |
Yes |
— Modbus RTU device |
Yes |
— USS |
Yes; Available as library function |
Interface types |
RS 485 |
● Transmission rate, max. |
250 kbit/s |
Protocols |
Integrated protocols |
Freeport |
— Telegram length, max. |
4 kbyte |
— Bits per character |
7 or 8 |
— Number of stop bits |
1 (Standard), 2 |
— Parity |
no parity (standard); even, odd, mark (parity bit always 1); space (parity bit always 0) |
Modbus RTU master |
— Address area |
1 through 65535 (Standard Modbus addressing) |
— max. number of devices |
247; slave numbers 1 through 247, per MODBUS network segment maximum 32 devices, additional repeaters needed to expand the network to maximum configuration |
protocols / Modbus RTU device / header |
— Address area |
1 through 65535 (Standard Modbus addressing) |
Interrupts/diagnostics/status information |
Diagnostics function |
Yes |
Diagnostics indication LED |
● DIAG LED |
Yes |
● for status of the outputs |
Yes |
Degree and class of protection |
IP degree of protection |
IP20 |
Standards, approvals, certificates |
CE mark |
Yes |
CSA approval |
No |
UL approval |
Yes |
cULus |
Yes |
FM approval |
No |
RCM (formerly C-TICK) |
Yes |
KC approval |
Yes |
Marine approval |
No |
Ambient conditions |
Free fall |
● Fall height, max. |
0.3 m; five times, in product package |
Ambient temperature during operation |
● horizontal installation, min. |
-20 °C |
● horizontal installation, max. |
60 °C; at max. voltages and max. specification |
● vertical installation, min. |
-20 °C |
● vertical installation, max. |
50 °C; at max. voltages and max. specification |
Ambient temperature during storage/transportation |
● min. |
-40 °C |
● max. |
70 °C |
Air pressure acc. to IEC 60068-2-13 |
● Operation, min. |
540 hPa |
● Operation, max. |
1 140 hPa |
● Storage/transport, min. |
540 hPa |
● Storage/transport, max. |
1 140 hPa |
Altitude during operation relating to sea level |
● Installation altitude, min. |
-1 000 m |
● Installation altitude, max. |
5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
Relative humidity |
● Operation, max. |
95 %; no condensation |
Vibrations |
● Vibration resistance during operation acc. to IEC 60068-2-6 |
3.5 mm from 5 - 8.4 Hz, 1g from 8.4 - 150 Hz |
● Operation, tested according to IEC 60068-2-6 |
Yes |
Shock testing |
● tested according to IEC 60068-2-27 |
Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
Pollutant concentrations |
● SO2 at RH < 60% without condensation |
S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60 % condensation-free |
Mechanics/material |
Enclosure material (front) |
|
● Plastic |
Yes |
Dimensions |
Width |
15 mm |
Height |
62 mm |
Depth |
63 mm |
Weights |
Weight, approx. |
29 g |